WINGONEER trademark Reg.NO:4747611
Description:
1. Wide voltage (5 ~ 36V), most devices can be used, very convenient;
2. The interface is clear and simple, powerful, easy to understand, meet almost all your needs;
3. There is a key stop function (STOP key), with reverse polarity protection, reverse polarity does not burn;
4. Add the sleep mode function, after enabling, without any operation within 5 minutes, turn off the monitor automatically;
Any key to wake up;
5. You can set a different OP, CL, LOP parameters, which are independent of each other, were saved;
6. When all settings automatic power-down save parameters.
Operating mode:
P1 mode: after the trigger signal, the relay is turned OP time, and then disconnect; in the OP time, as follows
P1.1: Invalid signal triggered again
P1.2: Re-timing signal is triggered again
P1.3: Reset signal is triggered again, the relay off, stop counting;
P-2: to the trigger signal, relay off for time CL, OP relay conduction time, after the counting is finished, disconnect relay;
P3.1: After the trigger signal to the relay turned OP time, relay off CL time, then the operation cycle, to signal to the relay off, stop the counting once again within the loop; cycles (LOP) can be set;
P3.2: After power without triggering signal, the relay is turned OP time, relay off CL time, cycle the operation; cycles (LOP) can be set;
P-4: signal holding function if there is a trigger signal, timing is cleared, the relay remains on; when the signal disappears, after timing OP disconnect relay; timer period, then there is a signal, the timing is cleared;
Packing List:
1x WINGONEER Switch module
Description:
1. Wide voltage (5 ~ 36V), most devices can be used, very convenient;
2. The interface is clear and simple, powerful, easy to understand, meet almost all your needs;
3. There is a key stop function (STOP key), with reverse polarity protection, reverse polarity does not burn;
4. Add the sleep mode function, after enabling, without any operation within 5 minutes, turn off the monitor automatically;
Any key to wake up;
5. You can set a different OP, CL, LOP parameters, which are independent of each other, were saved;
6. When all settings automatic power-down save parameters.
Operating mode:
P1 mode: after the trigger signal, the relay is turned OP time, and then disconnect; in the OP time, as follows
P1.1: Invalid signal triggered again
P1.2: Re-timing signal is triggered again
P1.3: Reset signal is triggered again, the relay off, stop counting;
P-2: to the trigger signal, relay off for time CL, OP relay conduction time, after the counting is finished, disconnect relay;
P3.1: After the trigger signal to the relay turned OP time, relay off CL time, then the operation cycle, to signal to the relay off, stop the counting once again within the loop; cycles (LOP) can be set;
P3.2: After power without triggering signal, the relay is turned OP time, relay off CL time, cycle the operation; cycles (LOP) can be set;
P-4: signal holding function if there is a trigger signal, timing is cleared, the relay remains on; when the signal disappears, after timing OP disconnect relay; timer period, then there is a signal, the timing is cleared;
Packing List:
1x WINGONEER Switch module