EI type isolation control transformer
Transformer model: 1210KY
Primary: current/open circuit 83mA maximum
Loss power: 2W maximum no-load temperature rise ? 25K
Secondary: open-circuit voltage: 13.8VAC ± 5%, rated load voltage: 12 ± 5%, rated current: 0.83A
Power factor: 90%
Input terminal with temperature overload protection: 2A/125 ?/250V
Product size: 2.95in × 1.73in × 1.65in
Installation configuration: 2 feet installation space 2.48in
Insulation class: Class II
Insulation strength test (withstand voltage test):
Primary and core AC 3KV 5mA 3Sec
Secondary and core AC 3KV 5mA 3Sec
Primary and secondary AC 3KV 5mA 3Sec without breakdown
Insulation resistance: DC 500V ? 100 M ?
Quality: high quality silicon steel sheet/low loss, high temperature resistant lead, nylon flame-retardant rubber core, high temperature insulation Mara tape, pure copper wire production, full power. Safe, stable and reliable.